* Remove Application Insights implementation and implement new Sentry.IO SDK * Remove test exception.
88 lines
2.9 KiB
C#
88 lines
2.9 KiB
C#
using System.Collections.Generic;
|
|
using Sentry;
|
|
using Serilog;
|
|
using Serilog.Core;
|
|
using Serilog.Exceptions;
|
|
using Wino.Core.Domain.Interfaces;
|
|
|
|
namespace Wino.Services;
|
|
|
|
public class WinoLogger : IWinoLogger
|
|
{
|
|
private readonly LoggingLevelSwitch _levelSwitch = new LoggingLevelSwitch();
|
|
private readonly IPreferencesService _preferencesService;
|
|
private readonly IApplicationConfiguration _applicationConfiguration;
|
|
|
|
public WinoLogger(IPreferencesService preferencesService, IApplicationConfiguration applicationConfiguration)
|
|
{
|
|
_preferencesService = preferencesService;
|
|
_applicationConfiguration = applicationConfiguration;
|
|
|
|
RefreshLoggingLevel();
|
|
}
|
|
|
|
public void RefreshLoggingLevel()
|
|
{
|
|
#if DEBUG
|
|
_levelSwitch.MinimumLevel = Serilog.Events.LogEventLevel.Debug;
|
|
#else
|
|
_levelSwitch.MinimumLevel = _preferencesService.IsLoggingEnabled ? Serilog.Events.LogEventLevel.Information : Serilog.Events.LogEventLevel.Fatal;
|
|
#endif
|
|
}
|
|
|
|
public void SetupLogger(string fullLogFilePath)
|
|
{
|
|
// Make sure to set the diagnostic id for the telemetry converter.
|
|
// This call seems weird, but it is necessary to make sure the diagnostic id is set.
|
|
_preferencesService.DiagnosticId = _preferencesService.DiagnosticId;
|
|
|
|
// Initialize Sentry
|
|
SentrySdk.Init(options =>
|
|
{
|
|
options.Dsn = _applicationConfiguration.SentryDNS;
|
|
#if DEBUG
|
|
options.Debug = false;
|
|
#else
|
|
options.Debug = true;
|
|
#endif
|
|
options.AutoSessionTracking = true;
|
|
|
|
// Set user context
|
|
options.SetBeforeSend((sentryEvent, hint) =>
|
|
{
|
|
sentryEvent.User = new SentryUser
|
|
{
|
|
Id = _preferencesService.DiagnosticId
|
|
};
|
|
return sentryEvent;
|
|
});
|
|
});
|
|
|
|
Log.Logger = new LoggerConfiguration()
|
|
.MinimumLevel.ControlledBy(_levelSwitch)
|
|
.WriteTo.File(fullLogFilePath, retainedFileCountLimit: 3, rollOnFileSizeLimit: true, rollingInterval: RollingInterval.Day)
|
|
.WriteTo.Sentry(minimumBreadcrumbLevel: Serilog.Events.LogEventLevel.Information,
|
|
minimumEventLevel: Serilog.Events.LogEventLevel.Error)
|
|
.WriteTo.Debug()
|
|
.Enrich.FromLogContext()
|
|
.Enrich.WithExceptionDetails()
|
|
.CreateLogger();
|
|
}
|
|
|
|
public void TrackEvent(string eventName, Dictionary<string, string> properties = null)
|
|
{
|
|
SentrySdk.AddBreadcrumb(eventName, data: properties);
|
|
|
|
SentrySdk.ConfigureScope(scope =>
|
|
{
|
|
if (properties != null)
|
|
{
|
|
foreach (var prop in properties)
|
|
{
|
|
scope.SetTag(prop.Key, prop.Value);
|
|
}
|
|
}
|
|
});
|
|
}
|
|
}
|